Raised floor full/partial access

Full Access Steel F1

Suitable for office and retail environments. Full access floor has been developed for areas where cable management is required throughout the entire floor area and where it is likely to be extensively adjusted throughout the life of the floor. Durabella pedestals have been developed to accommodate isolation pads protecting the floor from any surrounding vibration. The system is effective in overcoming difficult site problems. (See data sheet for further information).

Floor Type

Ground thermal & levelled, First or above, thermal none levelling, First or above thermal levelling

Existing Floor

100 mm concrete, 150 mm concrete, 200 mm concrete, 250 mm concrete, Block & Beam, Don't know, Timber cross laminated timber (CLT)

Height on Top

55-70 mm, 70-85 mm, 85-100 mm, 100-115 mm, 115-130 mm, 130-145 mm, 150-1000 mm Contact office

Finishes

Carpet, Ceramics, Hard Wood, Heavy Stone Tile, Vinyl

Ancillary Requirements

None, Service void, Wet under floor heating, Service void with access panels for partial access floors (schools), Service void with access floor (retail + offices), Electric underfloor heating

Enhance loading

None, Increase load bearing up to 2.5 kn/m2, Increase load bearing up to 3.5 kn/m2, Increase loadbearing up to 5 kn/m2, Greater than 5 kn/m2 (confirm with office)

Enhance Sound proofing

No

Building Suitability

Cinema, Hospital, Offices, Residential, School / College / Academy, Student Accommodation, Theatre

Building Regulations

Standard Building Regulations

Partial Access

Suitable for Office and Retail environments. Partial access floor has been developed for areas where cable management or wherever access is necessary but where full access flooring is unlikely to be required.  Using access traps and cable management systems.

Floor Type

Ground thermal, Ground thermal & levelled, First or above, thermal none levelling, First or above acoustic none levelling, First or above thermal & acoustic none levelling, Basic floating levelling floor, First or above Acoustic levelling, First or above thermal levelling, First or above thermal & acoustic levelling

Existing Floor

100 mm concrete, 150 mm concrete, 200 mm concrete, 250 mm concrete, Block & Beam, Don't know, Standard floorboards with joist, Timber cross laminated timber (CLT)

Height on Top

55-70 mm, 70-85 mm, 85-100 mm, 100-115 mm, 115-130 mm, 130-145 mm

Ancillary Requirements

None, Service void, Wet under floor heating, Service void with access panels for partial access floors (schools), Service void with access floor (retail + offices), Electric underfloor heating

Enhance loading

None, Increase load bearing up to 2.5 kn/m2, Increase load bearing up to 3.5 kn/m2, Increase loadbearing up to 5 kn/m2, Greater than 5 kn/m2 (confirm with office)

Enhance Sound proofing

Airbourne 3dB, Airbourne 5dB, Airbourne 8dB, Impact 3dB, Impact 5dB, Impact 8dB

Finishes

Carpet, Ceramics, Hard Wood, Heavy Stone Tile, Vinyl

Building Suitability

Cinema, Community Hall, Hospital, Offices, Residential, School / College / Academy, Student Accommodation, Theatre

Building Regulations

Bream Standard, Robust Detail, Standard Building Regulations

Choose you product

If the product you require is not listed, please contact us

Receive all our news and updates